Industry-relevant training in Business, Technology, and Design to help professionals and graduates upskill for real-world careers.
Fun, engaging games to boost memory, math fluency, typing speed, and English skills—perfect for learners of all ages.
This chapter presents a thorough examination of magnetism and its application in transformers, detailing foundational magnetic circuit concepts, the operational principles of transformers, and the factors that affect their performance. It covers the mathematical formulation of electromagnetic induction, the analysis of transformer losses, efficiency, and various configurations like auto-transformers and three-phase connections. Furthermore, the content culminates in detailed assessments and practical exercises aimed at reinforcing the concepts learned.
Enroll to start learning
You’ve not yet enrolled in this course. Please enroll for free to listen to audio lessons, classroom podcasts and take practice test.
1.1
Magnetic Field, Magnetic Flux, And Magnetic Flux Density: Defining The Magnetic Environment
This section explores key concepts of magnetism, including magnetic field strength, magnetic flux, and magnetic flux density, providing foundational knowledge essential for understanding electromagnetic devices.
1.3
B-H Curve And Hysteresis: Understanding Material Magnetic Response
This section discusses the B-H curve, which represents the relationship between magnetic flux density and magnetic field strength in ferromagnetic materials, along with the hysteresis phenomenon that describes the lagging response of magnetization.
4.1.1
Copper Losses (Pcu )
Copper losses are the power dissipated as heat in the transformer's windings due to their electrical resistance. They are proportional to the square of the current ($I^2R$) and vary with the square of the load. \-- ## Medium Summary **Copper losses ($P\_{cu}$)**, also known as $I^2R$ losses or winding losses, represent the power dissipated as heat in the primary and secondary windings of a transformer due to their inherent electrical resistance. Since these losses are proportional to the square of the current flowing through the windings and the resistance of the windings, they are highly dependent on the transformer's load. At no-load, copper losses are zero or negligible, while at full-load, they are at their maximum. These losses directly impact a transformer's efficiency, as the dissipated energy is lost to the environment as heat rather than being transferred to the load. \-- ## Detailed Summary ### Detailed Summary This section meticulously examines **Copper Losses ($P\_{cu}$)**, a critical component of energy dissipation in transformers. Also known as **$I^2R$ losses** or **winding losses**, these represent the power converted into heat within the conductive windings of the transformer due to their inherent electrical resistance. * **Physical Origin:** * Transformer windings are made of conductive materials, primarily copper (hence "copper losses") or sometimes aluminum. * All real conductors possess a certain amount of electrical resistance. * When current flows through a resistive conductor, electrical energy is converted into thermal energy (heat). This phenomenon is described by Joule's Law. * **Mathematical Dependencies:** * **Joule's Law:** The fundamental principle governing copper losses is $P = I^2R$. * In a transformer, there are two windings (primary and secondary), each contributing to copper losses: $P\_{cu} = I\_1^2 R\_1 + I\_2^2 R\_2$ Where: * $P\_{cu}$: Total copper losses in Watts (W). * $I\_1$: RMS current flowing through the primary winding (A). * $R\_1$: Electrical resistance of the primary winding (Ω). * $I\_2$: RMS current flowing through the secondary winding (A). * $R\_2$: Electrical resistance of the secondary winding (Ω). * **Dependency on Load:** Copper losses are **highly dependent on the load current**. * At **no-load**, the primary current ($I\_1$) is minimal (only magnetizing current and core loss current), and the secondary current ($I\_2$) is zero. Therefore, copper losses are practically zero or negligible at no-load. * As the **load increases**, both $I\_1$ and $I\_2$ increase proportionally. Since the losses are proportional to the *square* of the current, copper losses increase rapidly with increasing load. * At **full-load** (rated current), copper losses are at their maximum value. * **Representation as a Fraction of Full Load:** Often, copper losses are expressed as a fraction of their full-load value. If 'x' is the fractional load (e.g., x = 0.5 for half-load, x = 1 for full-load), then: $P\_{cu} = x^2 P\_{cu,FL}$ Where $P\_{cu,FL}$ is the copper loss at full load. This highlights the quadratic relationship. * **Impact on Transformer Performance:** * **Efficiency:** Copper losses directly reduce the efficiency ($\\eta$) of a transformer. The energy dissipated as heat is lost and not transferred to the load. $\\eta = \\frac{P\_{out}}{P\_{in}} = \\frac{P\_{out}}{P\_{out} + P\_{losses}} = \\frac{P\_{out}}{P\_{out} + P\_{core} + P\_{cu}}$ * **Heating:** The heat generated by copper losses must be dissipated by the transformer's cooling system. Excessive copper losses can lead to overheating, insulation degradation, and reduced lifespan of the transformer. * **Voltage Regulation:** The voltage drop across the winding resistances contributes to the overall voltage drop in the transformer, affecting its voltage regulation. * **Methods for Minimization:** * **Using High-Conductivity Materials:** Employing copper (which has very low resistivity) for windings. * **Increasing Conductor Cross-Sectional Area:** For a given length, a larger cross-sectional area (thicker wire) leads to lower resistance ($R = \\rho \\frac{L}{A}$). This is a common design choice, but it increases the size and cost of the transformer. * **Minimizing Winding Length:** Shorter winding lengths reduce resistance. * **Optimized Design:** Careful design of the winding geometry and number of turns to balance desired voltage ratios and current-carrying capabilities with acceptable resistance. * **Determination (from Experimental Tests):** * Copper losses are primarily determined from the **Short-Circuit (SC) Test** of a transformer. * In the SC test, the secondary winding is short-circuited, and a reduced voltage is applied to the primary to circulate full-load current. Under these conditions, the core losses are negligible (due to very low applied voltage), so the measured input power largely represents the full-load copper losses ($P\_{sc} \\approx P\_{cu,FL}$). In summary, copper losses are an unavoidable consequence of current flow through resistive windings in a transformer. They are highly load-dependent, vary quadratically with current, and are a major factor influencing the transformer's efficiency, thermal performance, and voltage regulation. Minimizing them through material selection and design is a key aspect of efficient transformer engineering. \-- ## Narrative Content Sessions ### Session 1: What are Copper Losses? **Context:** Defining copper losses and their physical origin. **Narrative Content:** - **Teacher**: "So, we've talked about ideal transformers, where everything is perfect. But in the real world, transformers aren't 100% efficient. One big reason for this inefficiency is something called **Copper Losses**, often written as $P\_{cu}$. Can anyone guess why they're called 'copper losses'?" - **Student\_1**: "Because the windings are made of copper?" - **Teacher**: "Exactly\! And what do we know about any wire, even a good conductor like copper?" - **Student\_2**: "It has some resistance." - **Teacher**: "Right\! So, if current flows through a wire that has resistance, what happens to some of the electrical energy?" - **Student\_3**: "It turns into heat." - **Teacher**: "Precisely\! That's the core idea of copper losses. It's simply the power lost as heat in both the primary and secondary windings due to their inherent electrical resistance. It's essentially the 'friction' that electrons experience as they move through the copper wire." - **Teacher**: "We also call them $I^2R$ losses. Why do you think that name makes sense?" - **Student\_4**: "Because the formula for power lost in a resistor is $P = I^2R$." - **Teacher**: "Perfect\! So, copper losses are unavoidable in any real transformer because copper has resistance, and current has to flow through it." ### Session 2: How Copper Losses Depend on Load **Context:** Explaining the relationship between copper losses and transformer load. **Narrative Content:** - **Teacher**: "Now, consider how a transformer operates. When it's not connected to a load – what we call 'no-load' – how much current is typically flowing in the secondary winding?" - **Student\_1**: "None, or very little." - **Teacher**: "Exactly. And the primary current is just enough to establish the flux and cover tiny core losses. So, what would the copper losses be at no-load?" - **Student\_2**: "Very, very small, almost zero." - **Teacher**: "Right\! Now, imagine we connect a big load, like a factory full of machinery. What happens to the currents in both the primary and secondary windings?" - **Student\_3**: "They increase a lot, up to their full-load ratings." - **Teacher**: "And since copper losses are $I^2R$, what's going to happen to these losses as the current goes up?" - **Student\_4**: "They'll increase quadratically, much faster than the current itself." - **Teacher**: "Excellent\! So, if a transformer is operating at half its full load, what fraction of its full-load copper losses would it be experiencing?" - **Student\_1**: "Half the current squared, so $(0.5)^2 = 0.25$, or one-quarter of the full-load copper losses." - **Teacher**: "Spot on\! This means that copper losses are highly load-dependent and are at their maximum when the transformer is operating at full load. This is a crucial distinction from core losses, which are relatively constant." ### Session 3: Impact and Minimization of Copper Losses **Context:** Discussing the effects of copper losses and how engineers try to reduce them. **Narrative Content:** - **Teacher**: "So, we know copper losses generate heat. What are the main problems this heat causes for a transformer?" - **Student\_1**: "It reduces efficiency, because that energy isn't going to the load." - **Teacher**: "Absolutely. That's power that's simply being wasted as heat. What else?" - **Student\_2**: "It can cause the transformer to overheat, which can damage the insulation or shorten its lifespan." - **Teacher**: "Precisely. Overheating is a major concern. So, as engineers, how do we try to minimize these losses when designing a transformer?" - **Student\_3**: "Use very good conductors, like high-purity copper." - **Teacher**: "Good start\! What else can we do to reduce the resistance of the windings?" - **Student\_4**: "Make the wires thicker, or use wires with a larger cross-sectional area." - **Teacher**: "Excellent\! A thicker wire means lower resistance for a given length. Also, keeping winding lengths as short as possible helps. Finally, where do we typically measure copper losses experimentally?" - **Student\_1**: "From the Short-Circuit Test." - **Teacher**: "Exactly\! During a short-circuit test, we essentially force full current through the windings, and because the voltage is very low, the core losses become negligible, allowing us to measure almost pure copper losses. Understanding these losses is vital for designing efficient and reliable transformers."
4.1.2
Core Losses (Pc Or Piron Or Pcore )
Core losses are power dissipated as heat in a transformer's magnetic core due to alternating magnetic flux. They consist of hysteresis losses and eddy current losses, and are primarily dependent on frequency and voltage (or flux density), remaining relatively constant with load. \-- ## Medium Summary **Core losses ($P\_c$ or $P\_{iron}$ or $P\_{core}$)** are the energy losses that occur in the magnetic core of a transformer when it is subjected to an alternating magnetic flux. These losses are primarily due to two phenomena: **hysteresis losses** and **eddy current losses**. Unlike copper losses, which are load-dependent, core losses are largely **voltage and frequency dependent**, meaning they remain relatively constant regardless of the transformer's load, as long as the applied voltage and frequency are constant. Minimizing core losses is crucial for transformer efficiency, particularly for distribution transformers that operate under varying loads for long periods. \-- ## Detailed Summary ### Detailed Summary This section provides a comprehensive analysis of **Core Losses ($P\_c$ or $P\_{iron}$ or $P\_{core}$)**, which represent a significant portion of the energy dissipated in a transformer. These losses occur within the magnetic core material itself, due to the continuous alternation of the magnetic flux. They are primarily composed of two distinct components: **Hysteresis Losses** and **Eddy Current Losses**. * **Physical Origin:** * In an AC transformer, the applied alternating voltage to the primary winding creates an alternating current, which in turn establishes an **alternating magnetic flux** in the core. * The core material (typically silicon steel) is ferromagnetic, meaning it can be easily magnetized and demagnetized. However, this process is not perfectly efficient, leading to energy dissipation. * **Components of Core Losses:** * **a) Hysteresis Losses ($P\_h$):** * **Physical Origin:** These losses arise from the **reorientation of magnetic domains** within the ferromagnetic core material as the magnetic field continuously reverses its direction. When the core is magnetized, its magnetic domains align with the applied field. When the field reverses, these domains must reorient. This reorientation requires energy, which is dissipated as heat due to internal molecular friction. * **Dependence:** * **Frequency (f):** Hysteresis losses are **directly proportional to the frequency** of the alternating flux. A higher frequency means more reversals per second, thus more energy dissipated per second. * **Maximum Flux Density ($B\_{max}$):** Hysteresis losses are proportional to some power of the maximum flux density (typically $B\_{max}^{x}$, where x is the Steinmetz exponent, usually between 1.5 and 2.5, often approximated as $B\_{max}^2$). * **Volume of the Core (V):** More core material means more domains to reorient. * **Formula (Steinmetz Empirical Formula):** $P\_h = k\_h f B\_{max}^x V$ * $k\_h$: Hysteresis constant (material-dependent). * $f$: Frequency (Hz). * $B\_{max}$: Maximum flux density (Tesla, T). * $x$: Steinmetz exponent (empirical constant for the material). * $V$: Volume of the core (m$^3$). * **Minimization:** To minimize hysteresis losses, transformer cores are made of **soft magnetic materials** (like silicon steel) that have: * **Narrow hysteresis loops:** This indicates low retentivity and low coercivity, meaning they are easy to magnetize and demagnetize, thus requiring less energy for domain reorientation. * Low hysteresis constant ($k\_h$). * **b) Eddy Current Losses ($P\_e$):** * **Physical Origin:** When the alternating magnetic flux links with the conductive core material itself, it induces circulating currents within the core. These induced currents are called **eddy currents**. Since the core material has some electrical resistance, these eddy currents flow through a resistive path, leading to $I^2R$ power dissipation in the form of heat, similar to copper losses in windings. * **Dependence:** * **Frequency (f):** Eddy current losses are **proportional to the square of the frequency** ($f^2$). Higher frequency means a faster rate of change of flux, inducing larger EMFs and thus larger eddy currents. * **Maximum Flux Density ($B\_{max}$):** Proportional to the **square of the maximum flux density** ($B\_{max}^2$). * **Thickness of Laminations (t):** Most critically, eddy current losses are **proportional to the square of the lamination thickness** ($t^2$). * **Volume of the Core (V):** More core material means more space for eddy currents. * **Formula:** $P\_e = k\_e f^2 B\_{max}^2 t^2 V$ * $k\_e$: Eddy current constant (material-dependent, related to resistivity). * $f$: Frequency (Hz). * $B\_{max}$: Maximum flux density (Tesla, T). * $t$: Thickness of laminations (m). * $V$: Volume of the core (m$^3$). * **Minimization:** To minimize eddy current losses: * **Lamination:** The core is built from thin sheets (laminations) that are electrically insulated from each other. This breaks up the eddy current paths, drastically increasing the resistance encountered by the induced currents and thereby reducing their magnitude. Without laminations, eddy currents would be enormous. * **High Resistivity Material:** Using core materials (like silicon steel) that have naturally higher electrical resistivity. * **Total Core Losses ($P\_c$):** $P\_c = P\_h + P\_e$ Since both $P\_h$ and $P\_e$ are proportional to $f$ and $B\_{max}$ (or $f^2$ and $B\_{max}^2$), and $B\_{max}$ is roughly proportional to $V/f$ (for constant voltage), core losses are primarily **voltage and frequency dependent**. * **Dependence on Load:** * **Constant with Load:** For a practical transformer, the voltage ($V\_1$) and frequency ($f$) of the input supply are usually held constant. Since core losses primarily depend on these two factors (and the core material properties), they are considered **relatively constant regardless of the load** connected to the secondary winding. * Even at no-load, when only a small magnetizing current flows, the core still experiences the full applied voltage and frequency, establishing the operating flux, so core losses are significant. * **Impact on Transformer Performance:** * **Efficiency:** Core losses directly reduce the efficiency of a transformer, as this energy is dissipated as heat and not transferred to the load. * **Heating:** The heat generated by core losses must be dissipated by the cooling system, contributing to the overall thermal management challenges. * **Continuous Dissipation:** Unlike copper losses, which vary with load, core losses are continuous as long as the transformer is energized, making them particularly important for distribution transformers that are always connected to the grid. * **Determination (from Experimental Tests):** * Core losses are primarily determined from the **Open-Circuit (No-Load) Test** of a transformer. * In the OC test, the secondary winding is left open, and rated voltage is applied to the primary. Under these conditions, the current drawn is very small (magnetizing current plus core loss current), so the copper losses ($I^2R$) are negligible. The measured input power in the OC test therefore largely represents the core losses ($P\_{oc} \\approx P\_c$). In conclusion, core losses are inherent energy dissipations within the magnetic core of an AC transformer, stemming from the continuous reversal of magnetic domains (hysteresis) and the induction of circulating currents (eddy currents). They are primarily dependent on voltage and frequency, remaining relatively constant with load, and are crucial considerations for transformer efficiency and thermal management, especially for continuously operating units. \-- ## Narrative Content Sessions ### Session 1: What are Core Losses? **Context:** Defining core losses and their general physical origin. **Narrative Content:** - **Teacher**: "Yesterday, we discussed copper losses, which happen in the windings. Today, we're moving inside the transformer, to the **Core**. Just like the windings, the core itself isn't perfect, and it also contributes to energy loss, which we call **Core Losses**, or sometimes iron losses, or $P\_{core}$. What's the main job of the transformer's core?" - **Student\_1**: "To carry the magnetic flux." - **Teacher**: "Exactly. And in an AC transformer, is that magnetic flux constant or changing?" - **Student\_2**: "It's constantly changing, it's alternating." - **Teacher**: "Perfect. This continuous changing, or alternating, magnetic flux within the core is the root cause of core losses. These losses come in two main forms. Can anyone recall what those two types are?" - **Student\_3**: "Hysteresis losses and eddy current losses." - **Teacher**: "That's right\! So, unlike copper losses which are about current in wires, core losses are about how the magnetic material itself behaves when exposed to a constantly flipping magnetic field." ### Session 2: Hysteresis Losses - The 'Magnetic Friction' **Context:** Detailing hysteresis losses. **Narrative Content:** - **Teacher**: "Let's dive into the first type: **Hysteresis Losses**. Imagine the core material is made up of tiny little magnets, called magnetic domains. When we apply a magnetic field, these domains try to align with the field. When the field reverses, they have to flip direction. What do you think happens when these tiny magnets constantly try to flip and re-align?" - **Student\_1**: "It takes energy, and maybe there's some friction?" - **Teacher**: "That's a great way to think about it\! It's like internal 'magnetic friction'. Each time these domains reorient, a small amount of energy is dissipated as heat. This 'memory' effect, where the material resists changes in its magnetic state, is called hysteresis. So, if the magnetic field is alternating faster, what happens to the hysteresis losses?" - **Student\_2**: "They would increase, because the domains are flipping more often." - **Teacher**: "Precisely\! So, hysteresis losses are directly proportional to the frequency. Also, the stronger the magnetic field, meaning higher flux density, the harder those domains have to work, so losses also increase with flux density. How do engineers try to minimize this 'magnetic friction'?" - **Student\_3**: "They use materials that are easy to magnetize and demagnetize, like soft magnetic materials." - **Teacher**: "Exactly\! Materials with narrow hysteresis loops, like silicon steel, are chosen for transformer cores." ### Session 3: Eddy Current Losses - The 'Induced Currents' **Context:** Detailing eddy current losses and their minimization. **Narrative Content:** - **Teacher**: "Now, for the second type: **Eddy Current Losses**. The core material is a conductor, right? What happens when a changing magnetic flux passes through a conductor?" - **Student\_1**: "It induces an EMF, and if there's a closed path, it induces a current." - **Teacher**: "Spot on\! That's Faraday's Law. These induced currents, flowing in circles within the bulk of the core material, are called **eddy currents**. And if currents flow through a resistive material, what kind of loss occurs?" - **Student\_2**: "$I^2R$ losses, or heat." - **Teacher**: "Exactly\! So, eddy current losses are essentially $I^2R$ losses, but they're happening *inside* the core material itself. Now, here's the clever part: How do engineers drastically reduce these eddy currents?" - **Student\_3**: "By making the core out of thin sheets, or laminations, that are insulated from each other." - **Teacher**: "Fantastic\! Why does that work?" - **Student\_4**: "Because it breaks up the path for the eddy currents. The induced currents have to flow in much smaller loops, and the insulation between the laminations increases the overall resistance of those paths, so the currents become much smaller." - **Teacher**: "Brilliant\! This lamination technique is incredibly effective. Eddy current losses also depend on the square of the frequency and the square of the flux density, and crucially, the square of the lamination thickness. So, thin laminations are key." ### Session 4: Load Independence and Measurement **Context:** Explaining why core losses are relatively constant and how they are measured. **Narrative Content:** - **Teacher**: "Unlike copper losses, which vary with load, core losses are considered relatively constant. Why do you think that is?" - **Student\_1**: "Because they depend on voltage and frequency, which usually stay constant regardless of how much load is connected." - **Teacher**: "That's the key\! The transformer's core experiences the full alternating voltage and frequency as long as it's plugged in, whether it's powering a tiny light bulb or a whole factory. So, these losses are continuous. This makes them especially important for distribution transformers that are always energized. Finally, if copper losses are measured with a short-circuit test, how do we measure core losses?" - **Student\_2**: "With an Open-Circuit (No-Load) Test." - **Teacher**: "Yes\! In that test, the secondary is open, so no load current flows, and copper losses are negligible. The power measured is almost entirely due to the core losses. So, these are the fundamental energy 'taxes' levied by the transformer's magnetic core."
4.4
All-Day Efficiency (Brief Explanation)
All-day efficiency (or energy efficiency) evaluates a transformer's performance over a **24-hour cycle**, considering varying load conditions. It's the ratio of total energy output to total energy input over a day, crucially accounting for constant core losses and variable copper losses to accurately assess distribution transformers. \-- ## Medium Summary **All-day efficiency**, also known as energy efficiency or commercial efficiency, is a critical metric for assessing the real-world performance of transformers, particularly **distribution transformers**. Unlike conventional efficiency, which is calculated at a specific load point, all-day efficiency considers the **total energy output versus total energy input over a 24-hour period**. This comprehensive measure is vital because distribution transformers are typically energized continuously, experiencing widely fluctuating loads throughout the day. It accounts for **constant core losses** (which occur 24/7) and **load-dependent copper losses** ($I^2R$ losses), providing a more accurate picture of the total energy conserved or lost by the transformer over time. \-- ## Detailed Summary ### Detailed Summary This section delves into **All-Day Efficiency**, a specialized and highly practical measure of transformer performance, particularly relevant for understanding the long-term energy consumption of certain types of transformers. Also known as **commercial efficiency** or **energy efficiency**, it offers a more realistic assessment than the conventional efficiency calculation. * **Definition:** All-day efficiency is defined as the ratio of the **total energy output** from the transformer to the **total energy input** to the transformer, calculated over a full **24-hour period**. It is expressed as a percentage. $\\text{All-Day Efficiency} (\\eta\_{all-day}) = \\frac{\\text{Energy Output (kWh) over 24 hours}}{\\text{Energy Input (kWh) over 24 hours}} \\times 100%$ * **Purpose and Importance:** * **Realistic Assessment:** Conventional efficiency is typically calculated for a specific load and power factor (e.g., at full-load or half-load). While useful for comparing instantaneous performance, it doesn't reflect how a transformer performs under the actual, fluctuating load conditions it experiences over an entire day. * **Focus on Distribution Transformers:** This concept is **critically important for distribution transformers**. These transformers are installed across power grids and are designed to be connected to the supply system 24 hours a day, year-round. However, the loads they supply vary significantly throughout the day (e.g., low load at night, peak load during working hours). * **Accounting for Different Loss Types:** * **Core Losses ($P\_c$ or $P\_{iron}$):** These losses are (practically) **constant** as long as the transformer is energized, regardless of the load. Therefore, they occur continuously for all 24 hours of operation. Their energy contribution over a day is $P\_c \\times 24$ hours (in Watt-hours or kilowatt-hours). * **Copper Losses ($P\_{cu}$):** These losses are **load-dependent**, varying with the square of the current ($I^2R$). They are zero (or negligible) at no-load and increase significantly as the load increases. For all-day efficiency, the copper losses must be calculated for *each specific load period* during the 24 hours and then summed up. * **Optimization for Continuous Operation:** A transformer might have a very high conventional efficiency at full load, but if its core losses are high, and it spends most of its time operating at light loads (where copper losses are low but core losses are still present), its all-day efficiency could be poor. All-day efficiency helps utilities and engineers select transformers that are optimized for minimal energy consumption over the typical load cycle of a day, leading to overall system energy savings. * **Calculation Methodology:** To calculate all-day efficiency, you need to know: 1. The **rated output** (kVA) of the transformer. 2. The **core losses ($P\_c$)** in Watts (obtained from the Open-Circuit Test). 3. The **full-load copper losses ($P\_{cu,FL}$)** in Watts (obtained from the Short-Circuit Test). 4. The **load cycle** for the 24-hour period: This involves knowing the percentage of full load and the duration (in hours) for which the transformer operates at that load throughout the day. 5. The **power factor** (typically assumed constant for simplicity, or varying as specified). The formula is expanded as: $\\eta\_{all-day} = \\frac{\\sum (\\text{Output Power (kVA)} \\times \\text{Load Factor} \\times \\text{Power Factor} \\times \\text{Hours})}{\\sum (\\text{Output Power (kVA)} \\times \\text{Load Factor} \\times \\text{Power Factor} \\times \\text{Hours}) + \\text{Total Core Energy Loss (kWh)} + \\text{Total Copper Energy Loss (kWh)}} \\times 100%$ Where: * **Energy Output (kWh) over 24 hours:** Sum of (Load in kVA \* Power Factor \* Hours for each load period). * **Total Core Energy Loss (kWh) over 24 hours:** $P\_c (\\text{in kW}) \\times 24 \\text{ hours}$. * **Total Copper Energy Loss (kWh) over 24 hours:** Sum of ($(\\text{Fractional Load})^2 \\times P\_{cu,FL} (\\text{in kW}) \\times \\text{Hours for each load period}$). * **Practical Implications:** * Utilities make significant investments in distribution transformers. Selecting transformers with higher all-day efficiency directly translates into **reduced operational costs** (lower electricity bills for losses) and a **smaller carbon footprint** over the transformer's lifespan. * It shifts the design focus for distribution transformers towards minimizing core losses, even at the expense of slightly higher copper losses, because core losses are a continuous drain, unlike copper losses which only occur when power is being delivered to a load. In essence, all-day efficiency provides a holistic view of transformer energy performance, making it an indispensable metric for power system planning and equipment selection where varying load profiles are the norm. \-- ## Narrative Content Sessions ### Session 1: What is All-Day Efficiency? **Context:** Introducing the concept of all-day efficiency and its distinction from conventional efficiency. **Narrative Content:** - **Teacher**: "We've discussed conventional transformer efficiency, which is usually calculated at a specific load, like full load. But imagine a transformer out on a pole, supplying power to a neighborhood. Does it always run at full load?" - **Student\_1**: "No, loads change. People go to work, come home, use more electricity at certain times." - **Teacher**: "Exactly\! So, if we just look at full-load efficiency, are we getting the whole picture of how much energy that transformer actually wastes over, say, an entire day?" - **Student\_2**: "Probably not, because its load is always changing." - **Teacher**: "That's where **All-Day Efficiency** comes in. It's a much more realistic way to evaluate a transformer, especially for these **distribution transformers** that are connected 24/7. Instead of looking at power ratios at one instant, we look at the **total energy output** versus the **total energy input** over a full 24-hour period. Why do you think this 'energy over time' perspective is so important?" - **Student\_3**: "Because losses happen over time, and some losses are always there." - **Teacher**: "You're thinking ahead\! That's our next point." ### Session 2: Why All-Day Efficiency Matters - The Role of Losses **Context:** Explaining how constant core losses and variable copper losses influence all-day efficiency. **Narrative Content:** - **Teacher**: "Let's remember our two main types of losses: **Core Losses** and **Copper Losses**. How do core losses behave with respect to the load?" - **Student\_1**: "They're pretty much constant, as long as the voltage and frequency are constant." - **Teacher**: "Right\! So, if a distribution transformer is energized 24/7, its core losses are happening for how many hours a day?" - **Student\_2**: "All 24 hours\!" - **Teacher**: "Exactly. Now, what about copper losses?" - **Student\_3**: "They vary with the square of the current, so they're low at light loads and high at full loads." - **Teacher**: "Excellent. So, at night, when most houses in the neighborhood are dark and the load is very light, what happens to the copper losses?" - **Student\_4**: "They become very small, almost zero." - **Teacher**: "But what about the core losses during that same period?" - **Student\_1**: "They're still there, constant\!" - **Teacher**: "Precisely. This is the crucial point: A transformer might be super efficient at full load (low copper losses then), but if it has high core losses and spends half the day almost idling, those constant core losses add up to a lot of wasted energy over 24 hours. All-day efficiency forces us to consider the total energy lost from *both* types of losses over the entire operating cycle, giving us a true picture of energy waste." ### Session 3: Calculating and Applying All-Day Efficiency **Context:** Discussing the calculation and practical implications. **Narrative Content:** - **Teacher**: "So, how do we actually calculate this? It's not just power anymore; it's **energy**. What's the unit of energy we typically use for electrical consumption?" - **Student\_1**: "Kilowatt-hours, or kWh." - **Teacher**: "Yes\! So, the formula for all-day efficiency is the total energy output in kWh over 24 hours, divided by the total energy input in kWh over 24 hours. To do this, we need to know the transformer's load profile – how many hours it's at full load, how many at half load, how many at no load, and so on. We then sum up the energy delivered during each period, and sum up the energy lost due to core losses (24 hours times $P\_c$) and copper losses (calculated for each load period, using the squared fractional load). Why do you think power companies care so much about this metric?" - **Student\_2**: "Because it costs them money to generate that wasted energy, and it impacts their carbon footprint." - **Teacher**: "Absolutely. Investing in transformers with higher all-day efficiency, even if they cost a little more upfront, leads to significant savings in operational costs and environmental benefits over the transformer's lifespan. It's about optimizing for the *actual* operating conditions, rather than just the peak performance."
References
Untitled document (12).pdfClass Notes
Memorization
What we have learnt
Final Test
Revision Tests
Term: Magnetic Flux
Definition: The total number of magnetic field lines passing through a given area, quantifying the overall amount of magnetism.
Term: Magnetomotive Force (MMF)
Definition: The driving force in a magnetic circuit responsible for establishing magnetic flux, analogous to voltage in electrical circuits.
Term: Transformer Efficiency
Definition: The ratio of useful output power to total input power, indicating how effectively a transformer converts electrical energy.
Term: AutoTransformer
Definition: A transformer with a single winding functioning as both primary and secondary, allowing for efficient voltage transformation with conductive transfer.