6.1.2 - Roofs
Enroll to start learning
You’ve not yet enrolled in this course. Please enroll for free to listen to audio lessons, classroom podcasts and take practice test.
Interactive Audio Lesson
Listen to a student-teacher conversation explaining the topic in a relatable way.
Introduction to Roof Live Load Reductions
🔒 Unlock Audio Lesson
Sign up and enroll to listen to this audio lesson
Today, we are diving into the importance of live load reductions for roofs. Can someone tell me why it's beneficial to reduce live load for roofs?
Maybe because the full load rarely occurs all at once?
Exactly! We use an equation from ASCE-7 which states that the reduced live load can be calculated as L_r = L_o R_1 R_2. Can anyone recall what L_o represents?
It's the original or unreduced live load, right?
Yes! Great job! Remember that L_r depends on both R_1 and R_2, the reduction factors. Let's keep these in context as we move forward.
Understanding Reduction Factors R_1 and R_2
🔒 Unlock Audio Lesson
Sign up and enroll to listen to this audio lesson
Now, let’s break down the reduction factors. For R_1, we have different cases based on the tributary area. What can you tell me about it?
R_1 is 1 for tributary areas less than 200 ft², and then it decreases as the area increases?
Yes! It decreases to 0.6 for areas greater than 600 ft². Can anyone explain what R_2 accounts for?
It considers the pitch of the roof, right? Based on the rise per foot or rise-to-span ratio?
Precisely! The design adjustments must reflect the roof's real conditions.
Application of Load Reduction Rules
🔒 Unlock Audio Lesson
Sign up and enroll to listen to this audio lesson
Let's apply what we've learned! Why do you think certain roof classes, like those for vehicle garages, aren’t allowed reduced loads?
Because they have significantly higher loads and need to support larger vehicles?
Exactly! For assembly usages too, loads remain unreduced. This relates back to overall safety. Always remember, L_max is critical.
Right, understanding the limits for what can't be reduced is just as important as knowing how to reduce.
Design Implications
🔒 Unlock Audio Lesson
Sign up and enroll to listen to this audio lesson
How does live load reduction influence overall design decisions for a building?
It can help in selecting smaller and lighter structural members.
Exactly, which can lead to cost savings and efficiency in materials without compromising safety.
So the balance between safety, usability, and economy is crucial in structural design.
Introduction & Overview
Read summaries of the section's main ideas at different levels of detail.
Quick Overview
Standard
The section provides detailed insights into the allowed reductions for roof live loads on ordinary flat, pitched, and curved roofs. It highlights the importance of tributary areas and formulas used to determine these reductions, alongside key factors affecting the design.
Detailed
Summary of Roofs
In structural engineering, the design of roofs is fundamental to ensuring the overall stability and safety of buildings. This section elaborates on the live load reduction methods applicable to ordinary flat, pitched, and curved roofs based on the guidelines established by ASCE-7. The primary equation used for reduction is given as:
L_r = L_o R_1 R_2
where L_r is the reduced roof live load, while L_o is the original live load. The reduction factors R_1 and R_2 are based on specific characteristics such as tributary area supported by the structural member and the roof pitch. Additionally, the section emphasizes that roofs supporting certain high live loads, such as those in passenger vehicle garages, are not eligible for reduction. Understanding these factors is crucial for proper load calculations and ensuring safety and serviceability in structural design.
Audio Book
Dive deep into the subject with an immersive audiobook experience.
Overview of Reduced Live Load for Roofs
Chapter 1 of 4
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
Ordinary flat, pitched, and curved roofs are permitted to be designed for a reduced roof live load in accordance with equation (4-2) from ASCE-7.
Detailed Explanation
This chunk introduces the concept of reduced live load specifically for roofs in construction. The ASCE-7 standards allow for certain roofs—whether they are flat, pitched, or curved—to be calculated with a lower live load than the typical maximum. This reduction is based on the understanding of how loads are distributed in structures, assuming not all areas of the roof will experience maximum load simultaneously.
Examples & Analogies
Think of a flat roof on a large building as a pizza. Just like not every slice of pizza gets the same toppings at the same time (maybe most toppings are on the slices that people are eating), not every part of the roof bears the same amount of weight. Therefore, engineers can design using a lower load because they expect only some areas to be 'topped' with weight at any given moment.
Equation for Reduced Roof Live Load
Chapter 2 of 4
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
L_r = L_o R_1 R_2
Where
0.58 ≤ L_r ≤ 0.96 (SI)
12 ≤ L_r ≤ 20 (USCU)
Detailed Explanation
This chunk presents the formula for calculating the reduced roof live load (L_r). The formula indicates that L_r is derived from the original unreduced live load (L_o) multiplied by two reduction factors (R_1 and R_2). The values for L_r are bounded within specific ranges for both SI and US customary units. This emphasizes that the reduction must remain within a set limit to ensure structural safety.
Examples & Analogies
Imagine you are packing a suitcase. The amount of clothes (original load) you plan to carry can be reduced depending on the size of your suitcase (reduction factors). If you know you can't pack too much, you ensure that your 'packed' weight meets specific limits to avoid exceeding the suitcase's capacity. Similarly, engineers adjust the load to remain within safe limits, ensuring the structure can support what's on it.
Determining Reduction Factors R1 and R2
Chapter 3 of 4
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
The reduction factors R_1 and R_2 shall be determined as follows:
For R_1:
1 for A_T ≤ 200ft²
1.5−0.001A_T for 200ft² < A_T < 600ft² (USCU)
0.6 for A_T ≥ 600ft²
For R_2:
1 for F ≤ 4
1.2−0.05F for 4 < F < 12 (USCU)
0.6 for F ≥ 12
Detailed Explanation
This chunk explains how the reduction factors, R_1 and R_2, are determined based on the tributary area (A_T) and the slope of the roof (F). R_1 considers two scenarios: if the area is less than or equal to 200 square feet, the factor is 1, and as the area increases to 600 square feet, a linear reduction is applied until a minimum of 0.6 is reached. R_2 is based on the rise of the roof where lower slopes yield a value of 1, and as the slope increases, the factor reduces to a minimum of 0.6.
Examples & Analogies
Consider baking a cake. If you have a small cake pan (A_T ≤ 200ft²), you can use all your batter (factor of 1), but if your pan is large, you might only need part of it (factors decreasing to 0.6) as more space means less batter per area. Similarly, for steep roofs (high F), the weight is distributed differently, requiring careful adjustments to ensure it's not overloaded.
Rise-to-Span Ratio for R2
Chapter 4 of 4
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
where, for a pitched roof, F = number of inches of rise per foot (in SI: F = 0.12 x slope, with slope expressed in percentage points) and, for an arch or dome, F = rise-to-span ratio multiplied by 32.
Detailed Explanation
This chunk defines how to calculate the rise-to-span ratio for pitched roofs and other roof types. For pitched roofs, F is calculated based on the height gained (rise) for every foot (span) of horizontal length. In engineering terms, this ratio helps in assessing how steep or flat a roof is, which is crucial when determining how much weight it can safely handle.
Examples & Analogies
Imagine climbing a hill. If the hill rises steeply in a short distance, you feel like you're climbing a staircase, which is similar to a steep roof. If the hill rises gradually over a long distance, it's like a gentle ramp. Steeper climbs (higher F) might be harder to navigate and require stronger structural support to ensure safety, just like steeper roofs must be evaluated for weight bearing.
Key Concepts
-
Reduction of Live Load: Roof live loads can be reduced using specified factors based on tributary area.
-
Tributary Area: Essential in determining the loads applied to structures.
-
Safety vs. Economy: Structural design must balance safety with material and construction costs.
Examples & Applications
A flat roof of a commercial building may have an original live load of 40 psf, which can be reduced to 30 psf using the R factors if the tributary area is large enough.
In a small residential structure, the pitched roof might see a reduction in live load if the area is less than the thresholds defined by ASCE-7.
Memory Aids
Interactive tools to help you remember key concepts
Rhymes
When the roof's area is tight, keep the load within limits, it's right.
Stories
Imagine a big umbrella in a rainstorm; it supports less load when the rain's light and can handle more when it's heavy. Just like roofs do!
Memory Tools
Remember R = Real area ratio; the smaller the area, the bigger the ratio.
Acronyms
L.R.A. - Live Load Reduction Allowed depending on the Area.
Flash Cards
Glossary
- Live Load
The load that is not permanent and may change during the lifecycle of the structure, such as people, furniture, and snow.
- Tributary Area
The area that contributes load to a specific structural member.
- Reduction Factor (R)
A numerical factor used to reduce the live load based on specific conditions.
Reference links
Supplementary resources to enhance your learning experience.