Measurement of Total Suspended Solids (TSS)
Enroll to start learning
You’ve not yet enrolled in this course. Please enroll for free to listen to audio lessons, classroom podcasts and take practice test.
Interactive Audio Lesson
Listen to a student-teacher conversation explaining the topic in a relatable way.
Introduction to Surrogates
🔒 Unlock Audio Lesson
Sign up and enroll to listen to this audio lesson
Today, we'll explore the concept of surrogates in environmental analysis. Surrogates are compounds similar to our target analyte—Total Suspended Solids (TSS). Can anyone explain why we use surrogates?
We use them to estimate how much of the actual substance we can recover during testing.
Exactly! By tracking the recovery of the surrogate, we can estimate how much TSS was lost during the analysis process.
How do we calculate the recovery though?
Good question! We add a known amount of the surrogate, measure what we recover, and then calculate the efficiency based on the initial amount added. It's essential for ensuring accuracy in our results!
Can you remind us what the initial amount is?
Sure! For this example, we typically add 1 mL of a 100 mg/L solution, resulting in 0.1 mg of surrogate.
To summarize, the use of surrogates helps us track recovery efficiency and ensures we get a reliable measurement of TSS.
Extraction Procedures
🔒 Unlock Audio Lesson
Sign up and enroll to listen to this audio lesson
Now, let's discuss how we extract TSS from water using hexane. Why is hexane chosen for this process?
Is it because it separates easily from water?
Exactly! Hexane is less dense than water, allowing for a clear separation after extraction. You shake the mixture to facilitate the transfer of solids.
How much hexane are we typically using?
We use 50 mL initially for extraction. Remember, after shaking, we can only take 40 mL for analysis due to separation limitations.
So we do liquid-liquid extraction?
Correct! This method effectively isolates suspended solids from the water sample for further analysis.
This process is crucial as it yields cleaner extracts, improving our chances for accurate measurements.
Concentration of Extracts
🔒 Unlock Audio Lesson
Sign up and enroll to listen to this audio lesson
Once we've extracted our sample, we typically need to concentrate it. Can anyone guess why?
To improve the detection of tiny amounts of solids in the sample?
Absolutely! By concentrating 40 mL to 1 mL, we're enhancing our chances of detecting trace levels.
What method do we use for concentration?
We often use evaporation techniques, sometimes employing a rotary evaporator to achieve this.
When do we know if our concentration step is necessary?
If we expect very low concentrations, concentrating the sample increases our analytical response, making trace detection feasible.
To summarize, concentrating the extract prior to analysis is vital for enhancing the detection of the suspended solids in our samples.
Calibration and Recovery Calculations
🔒 Unlock Audio Lesson
Sign up and enroll to listen to this audio lesson
Now, let’s discuss calibration. Why is it important in our analysis?
To ensure we can convert the instrument response into a concentration value?
Exactly! Calibration curves help us relate the detected signal to the actual mass of the analyte.
How do we calculate our recovery rate using calibration?
We use the calibration equation—like the one provided in your notes—to relate the instrument response to the concentration of the analyte injected.
Are we comparing what we found with what we initially added?
That's right! We compare to ensure that our calculated recovery reflects the efficiency of our extraction and analysis methods.
In summary, reliable calibration methods enable us to make accurate quantitative assessments of TSS in our samples.
Sample Volume Requirements
🔒 Unlock Audio Lesson
Sign up and enroll to listen to this audio lesson
Let’s wrap up by discussing the minimum volume requirements for TSS measurement. Why is this important?
To ensure we can detect the suspended solids accurately, right?
Correct! If we don’t collect enough sample volume, we might fall below the minimum detection limits.
What factors influence how much water we should collect?
Primarily, it’s the concentration of TSS expected in the sample and the sensitivity of our analysis tools.
And what do we do if our initial sample concentration is too high for our balance?
In that case, we dilute the sample before measuring to fit within the instrument's range.
To summarize, determining the correct sample volume is critical for accurate TSS measurement and analysis.
Introduction & Overview
Read summaries of the section's main ideas at different levels of detail.
Quick Overview
Standard
The section elaborates on how to measure Total Suspended Solids (TSS) by introducing the concept of surrogates, detailing extraction techniques using hexane, and the importance of calibration in quantifying analytes. It emphasizes recovery calculations to understand material loss during the procedure and provides necessary calculations for estimating required sample volumes based on detection limits.
Detailed
Measurement of Total Suspended Solids (TSS)
In this section, we focus on measuring Total Suspended Solids (TSS) in environmental samples, primarily through the method of filtration followed by gravimetric analysis. The measurement involves adding a surrogate substance, which behaves similarly to the analyte of interest (TSS), to track the recovery efficiency during analysis.
Key Points Covered:
- Surrogates in Analysis: The use of surrogates is crucial in analyzing samples, as they help estimate the recovery of the actual analyte. A clear example shows how adding 1 mL of a 100 mg/L surrogate solution helps quantify the loss of the analyte during processing.
- Extraction Procedure: The measurement process involves extracting the sample using a specified volume of hexane. The importance of understanding the solvent's role in extracting suspended solids is underscored.
- Concentration Steps: Concentrating the extract (40 mL reduced to 1 mL) is necessary to detect trace levels effectively and ensure that sufficient response data is obtained from subsequent analytical instruments.
- Calibration and Recovery Calculations: The section emphasizes the role of calibration curves, detailing how to convert instrument responses to mass concentrations, and how to back-calculate to find amounts of TSS in original samples.
- Sample Volume Requirements: The section discusses the importance of determining the minimum sample volume to ensure accurate detection and analysis of TSS, particularly focusing on methods to overcome potential dilution effects.

This thorough examination of TSS measurement provides a foundational understanding of environmental sampling methods relevant to water quality monitoring.
Youtube Videos
Audio Book
Dive deep into the subject with an immersive audiobook experience.
Introduction to TSS Measurement
Chapter 1 of 6
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
Estimate the minimum water sample that is required for the measurement of TSS in the range 10-30 milligram per liter using a method of filtration followed by gravimetric analysis. A 4-digit balance is being used to weigh.
Detailed Explanation
To measure Total Suspended Solids (TSS), we first need to know the concentration of TSS we want to measure, which is between 10 and 30 mg/L. We calculate the minimum sample volume needed to ensure our measurement is reliable. Assuming we use a filtration method, the amount of solids we need to collect must be greater than a defined detection limit, which we derive from our equipment's specifications.
Examples & Analogies
Imagine wanting to find the amount of sugar in a large container of water. If your measuring spoon (balance) can only accurately measure up to a certain amount but you suspect there could be even more sugar, you'd want to take a bigger scoop (water sample) from the container to be sure you get a measurable amount for testing.
Calculating Minimum Sample Volume
Chapter 2 of 6
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
So here prior I know, so what I am asking is TSS is milligram per liter multiplied by volumes in liter will give you a mass m3 suspended solid in milligrams, yeah. What they are asking is how much is this? What is the minimum volume that is required okay?
Detailed Explanation
To calculate the mass of TSS, we multiply the TSS concentration (in mg/L) by the volume of water sampled (in liters). The equation we derive from this tells us that the volume must be sufficient to ensure that the mass of the extracted solids exceeds our instrument's minimum detection limit.
Examples & Analogies
Consider filling a jug with water to make soup. You know you need enough salt to properly season the soup. If a pinch of salt isn't enough, you need to fill the jug with a larger quantity of salt-water mix (sample volume) to ensure the flavor is noticeable.
Importance of Detection Limits
Chapter 3 of 6
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
This MDL is given in the calculation as mass MDL. It is a 4-digit balance, least count of 0.1. What is also given is standard deviation of random measurements of filter paper obtained as 5.4 milligrams.
Detailed Explanation
The Minimum Detection Limit (MDL) is a critical value determined by the balance's accuracy and the variability of measurements. It tells us the smallest amount of substance we can reliably detect. The standard deviation of filter paper measurements helps assess this variability; in this case, it's 5.4 mg, meaning that the detected mass can vary, impacting our accuracy.
Examples & Analogies
Think of using a precision scale to weigh your ingredients when baking. If the scale has a minimum reading limit (MDL), it won’t show an accurate weight if your ingredient is less than that reading. Just like a scale, our testing balances have limits to ensure we only report reliable measurements.
Choosing the Right Sample Volume
Chapter 4 of 6
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
Now the value of this TSS I am telling you is between 10 and 30, so it could be 10 milligrams per liter or it could be 30 milligrams per liter. Sometimes we are given this kind of things, a concentration in this range, so what will be your minimum?
Detailed Explanation
When determining how much volume of water to sample, we need to choose a volume that will maximize our ability to detect TSS. In this case, if we want to be sure that the sample we take (like 1.62 liters) has a better chance of yielding measurable TSS, we might aim for the higher concentration limit (30 mg/L), allowing us to collect enough solid for analysis.
Examples & Analogies
If you're trying to fill a bucket from a stream where the water may have floating debris, collecting a larger bucket full ensures you'll get enough floating debris for analysis than if you were dipping a small cup into the stream. You want to ensure you have enough to test and find what's there, not just a few particles.
Handling High Solids Concentration Samples
Chapter 5 of 6
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
If you are expecting that the concentration is going to cross the limit of the measurement, this one measurement, what we usually do? We dilute.
Detailed Explanation
If we find that our sample has too many solids and exceeds our balance's measurement capacity, we can dilute our sample to bring it within a measurable range. This is a common practice in analytical chemistry to ensure accurate and reliable measurements.
Examples & Analogies
Imagine if your paint is too thick to work with. You'd typically add water to thin it down, making it easier to handle and apply — similarly, dilution makes the sample manageable for our instruments.
Risk Assessment in TSS Testing
Chapter 6 of 6
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
So for example, if I am taking 1.6 liters and still my amount of mass that I am seeing is below the detection limit that corresponds to a concentration of TSS, which is less than 10 milligrams per liter.
Detailed Explanation
During the testing process, if our sample remains below the detection limit after testing, we may need to reassess our sampling strategy. If TSS is expected to be low, should we collect more sample? If the concentration is above limits and poses health risks, measures need to be adjusted to ensure compliance with safety standards.
Examples & Analogies
Consider safety inspections for food quality: if a restaurant consistently fails to meet health standards in a small food sample, they may need to check larger batches regularly to avoid safety issues. Similarly, we may need to assess more extensive water samples.
Key Concepts
-
Surrogates enhance recovery tracking during TSS analysis.
-
Hexane is a common solvent for extracting suspended solids.
-
Concentration of extracts improves detection of TSS.
-
Calibration is crucial for accurate TSS quantification.
-
Sample size must be adequate to avoid below-detection limits.
Examples & Applications
Adding a 1 mL solution of 100 mg/L surrogate to track the recovery of TSS.
Concentrating 40 mL of hexane extract to 1 mL to improve response for the analysis.
Memory Aids
Interactive tools to help you remember key concepts
Rhymes
Surrogates to track and test, TSS measurement is the best!
Stories
Once there was a chemist named Sam who wanted to measure TSS in a lake. He used a surrogate named 'Hexy' who helped him extract and analyze the solids, ensuring he got the most accurate results!
Memory Tools
Remember S.H.C.R. for TSS: Surrogates Extract, Concentrate, and Recovery!
Acronyms
TSS
Tidy Suspended Solids - Always keep your sample in a tidy state for better results.
Flash Cards
Glossary
- Total Suspended Solids (TSS)
The solid particles suspended in water, which can be either organic or inorganic.
- Surrogate
A compound added to the sample for analytical measure, expected to behave similarly to the analyte.
- Extraction
A process of separating a substance from a mixture, usually using a solvent.
- Calibration
The process of determining the relationship between instrument output and known concentrations of analyte.
- Concentration
The process of reducing the volume of a solution to increase the amount of solute per unit volume.
- Recovery Rate
The percentage of an analyte recovered from a sample through extraction and analysis.
Reference links
Supplementary resources to enhance your learning experience.