2.1 - Transportation of the Sample
Enroll to start learning
You’ve not yet enrolled in this course. Please enroll for free to listen to audio lessons, classroom podcasts and take practice test.
Interactive Audio Lesson
Listen to a student-teacher conversation explaining the topic in a relatable way.
Importance of Sample Transportation
🔒 Unlock Audio Lesson
Sign up and enroll to listen to this audio lesson
Today, we will explore why the transportation of samples is so critical in environmental analysis. Can anyone tell me what might happen to a sample during transport?
It might get contaminated or lose some of the substances we're testing for.
Great point! Losses can occur due to various factors. One major concern is volatilization. What do you think that means?
Is it when the chemicals evaporate or escape from the liquid sample?
Exactly! That’s why we use airtight containers to minimize exposure to air. Remember the acronym H.E.A.D. - Headspace, Evaporation, Airtight, and Delay - to help recall the importance of reducing headspace during transport. If we can minimize headspace, we can reduce the risk of losses.
So, if we cover these steps, the analytes should remain intact?
Mostly, yes! Always keeping in mind the 3 main causes of losses: volatilization, reaction, and adsorption.
What about the reactions? Can they happen even during transport?
Certainly! Reactions can occur with other materials in the sample, which is why time is crucial. The longer we wait, the more chances there are for reactions to occur, leading to potential analyte loss. Always keep track of time!
So, to summarize: always use airtight containers, minimize headspace, and monitor transport time to reduce losses due to volatilization, reaction, and adsorption.
Recognizing Analyte Losses
🔒 Unlock Audio Lesson
Sign up and enroll to listen to this audio lesson
Now that we discussed the causes of analyte loss, let’s dive deeper into each type. Can someone explain what happens during adsorption?
Isn’t that when analytes stick to surfaces, like the container walls?
Yes, precisely! This is why we generally prefer glass containers for organic samples. Glass minimizes adsorption. Can you think of why it matters which type of container we use?
If we use plastic for organic samples, they might stick to the walls instead of being in the solution.
Spot on! And remember, surface interactions can significantly alter our results. So, maintaining cleanliness is key. Who can remind us of the steps required to check for these losses in our samples?
We can run blank analyses to check for any background contamination.
Yes! A blank analysis serves as a control. Can someone share how the results from a blank might impact our confidence in sample results?
If the blank shows contamination, we can't be sure that our results are accurate.
Exactly! Summing up: adsoprtion can lead to analyte losses; correct container choice is crucial, and running blank analyses helps us maintain confidence in our results.
Mitigating Analyte Losses During Transportation
🔒 Unlock Audio Lesson
Sign up and enroll to listen to this audio lesson
Having identified the potential losses, let’s discuss prevention methods. What can we do to minimize these losses effectively?
We can control the temperature during transportation, right?
Great thought! Temperature control is vital as lower temperatures reduce evaporation and degradation reactions. Can anyone else think of an effective strategy?
Using inert materials for the caps or containers helps reduce adsorption.
Absolutely! Avoid contamination by using clean glassware as well. What’s the time frame we should be mindful of during transport?
We need to transport the samples as fast as possible to limit the time they are exposed.
Correct! The less time they have to undergo reactions, the better. Always keep the transport period short, and handle your samples with care. To summarize, use airtight, clean containers, manage operational temperatures, and act quickly to preserve sample integrity.
Quality Assurance and Quality Control
🔒 Unlock Audio Lesson
Sign up and enroll to listen to this audio lesson
Quality assurance plays a huge role in environmental analysis. Can someone explain why it's vital?
It ensures our results are accurate and highlights any issues in our analysis process.
Exactly! What are some common QA/QC practices we might implement?
Running replicate samples helps us see if our process is reliable.
Yes! Replicates are important for showing the consistency of our results. Can anyone recall what a laboratory control sample is used for?
It lets us know our recovery of analytes is on track through the analysis process.
Great! We want to establish a baseline of accuracy. To wrap up, always conduct QA and QC practices to ensure our results reflect true environmental conditions and verify the analyte content.
Introduction & Overview
Read summaries of the section's main ideas at different levels of detail.
Quick Overview
Standard
The section highlights key factors that contribute to analyte losses during sample transportation, such as volatilization, reaction, and adsorption. It emphasizes the importance of proper sample handling, storage conditions, and quality assurance practices to maintain the integrity of environmental samples.
Detailed
Transportation of the Sample
Transportation of samples in environmental analysis is a crucial phase that can significantly influence the accuracy of analytical results. In this section, we discuss the main types of analyte losses that occur during transportation, which include:
- Volatilization: This refers to the evaporation of the analyte from the sample, especially relevant for volatile compounds in water samples. To minimize volatilization, samples should be stored in airtight containers to reduce headspace.
- Reaction: During the transportation phase, analytes may undergo various chemical reactions, including biodegradation and interactions with other substances in the sample. As time progresses, these reactions can result in significant losses of the target analyte.
- Adsorption: This process occurs when analytes adhere to solid surfaces, potentially leading to losses if the sample container is not chosen appropriately. The material of the container (glass is preferred for organic samples) impacts adsorption behavior.

Quality assurance (QA) and quality control (QC) measures are vital for ensuring that any losses during transportation do not compromise analytical results. Implementing strategies such as using appropriate containers, maintaining low temperatures, and conducting recovery assessments can enhance the reliability of environmental analyses.
Youtube Videos
Audio Book
Dive deep into the subject with an immersive audiobook experience.
Introduction to Analyte Losses
Chapter 1 of 6
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
One of the concerns in chemical analysis for environmental samples is the issue of analyte losses. This is important from the point of view of the confidence people have in the measurement and because this is also subject to litigation. Therefore, people would like to have some confidence in terms of the accuracy of the results.
Detailed Explanation
Analyte losses refer to the reduction in the amount of the substance being measured during various stages of sample handling. This is crucial because accurate environmental measurements are often used for legal and regulatory decisions. If the results reflect a loss in the analyte, decisions based on these results may be flawed or incorrect, which could lead to substantial implications.
Examples & Analogies
Think of this like a chef who is trying to recreate a famous dish. If they lose some of the critical ingredients while cooking, the final product won't taste right. Similarly, if environmental samples lose their analytes during transportation, the measurements won't represent reality.
Stages of Analyte Loss
Chapter 2 of 6
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
The possible analyte losses occur during transportation, storage, processing, and finally during analysis with the chemical instrument. So, let us first look at transport. Transport, for example, if you are taking a water sample, various kinds of errors can occur during the transport.
Detailed Explanation
Analyte losses can occur at different stages: transportation involves moving the sample from the collection site to the laboratory. During this phase, various errors or losses can happen, affecting the reliability of the sample. Understanding each stage helps identify where to tighten controls and reduce potential losses.
Examples & Analogies
Imagine sending a delicate package through a delivery service. If the package isn’t handled carefully, it could break or lose important contents during transit. In the same way, if environmental samples are not transported properly, they can lose important chemicals crucial for accurate analysis.
Types of Analyte Losses
Chapter 3 of 6
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
Common processes that result in losses include: volatilization (evaporation of the analyte), reaction (like biodegradation), and adsorption (the analyte sticking to containers).
Detailed Explanation
There are common factors leading to analyte losses: Volatilization refers to the evaporation of volatile compounds, leading to reduced concentration in samples. Reactions might involve the analyte chemically transforming or degrading, especially in biological contexts. Adsorption happens when analytes cling to surfaces, like the container, leading to a reduction in the measurable amount. Each process is a kinetic one, meaning it can vary with time and conditions.
Examples & Analogies
Consider a bowl of soup left uncovered. After some time, it evaporates, losing liquid and flavor, similar to how volatile compounds can be lost during sample analysis. Additionally, if you leave a sugar packet on the counter, moisture could cause the sugar to stick to the packet (adsorption), reducing the usable quantity.
Preventing Volatilization
Chapter 4 of 6
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
To prevent volatilization, it's crucial to use airtight containers, ensure minimal air exposure, and control temperature during transport.
Detailed Explanation
Using airtight containers minimizes air contact with the sample, preventing the analytes from evaporating. Reducing headspace—air exposure within the container—and keeping samples at low temperatures can also inhibit volatilization and help maintain a sample's integrity. Temperature matters since warmer conditions can increase the likelihood of molecules evaporating.
Examples & Analogies
Think about preserving leftovers in the fridge. If you use a tightly sealed container, the food stays fresh longer because it's protected from air and temperature changes. Similarly, airtight containers and low temperatures keep samples from losing their components during transport.
Adsorption Considerations
Chapter 5 of 6
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
Adsorption occurs through solid surfaces during sample processing. For example, using glass containers for organic samples can help prevent analyte sticking.
Detailed Explanation
Adsorption can lead to analytes sticking to the walls of containers, which alters the concentration when the sample is analyzed. To reduce adsorption, it is vital to select appropriate container materials, like glass for organic compounds, to minimize the interaction. The choice of container is strategic to enhance the reliability of results.
Examples & Analogies
Imagine pouring oil into a plastic container. Some of the oil may cling to the sides, and you lose that oil when you try to pour it out. Using glass, in this case, would minimize that loss because oil does not stick to glass as strongly as it does to plastic.
Testing for Sample Recovery
Chapter 6 of 6
🔒 Unlock Audio Chapter
Sign up and enroll to access the full audio experience
Chapter Content
To assess the accuracy of sample analysis, we can measure recovery by understanding how much of the analyte has remained after all stages of handling.
Detailed Explanation
Measuring recovery involves comparing the initial amount of analyte in the sample to the amount found after analysis. By knowing what should be there versus what is measured, analysts can compute loss percentages and adjust their results accordingly. A recovery rate that deviates from expected values can signal potential issues in the analytical process.
Examples & Analogies
Think about counting marbles while packing a box. If you start with 100 marbles but only count 70 after opening it, you'll know that 30 are missing. Similarly, if a sample shows a recovery rate of 70% from a 100-unit starting point, we can calculate that 30% of the analyte was lost during processing.
Key Concepts
-
Volatilization: Refers to the evaporation of analytes from a sample, impacting accuracy.
-
Adsorption: The process where analytes cling to surfaces, leading to analyte losses.
-
Quality Assurance (QA): The measures taken to ensure analytical integrity.
-
Quality Control (QC): Operational methods used to monitor and evaluate the quality of results.
Examples & Applications
Sample contamination during transportation could result from a crack in the container leading to exposure to the atmosphere, increasing losses.
Using a clean glass bottle instead of a plastic one for housing organic analytes minimizes adsorption, thus preserving the sample's integrity.
Memory Aids
Interactive tools to help you remember key concepts
Rhymes
To keep analytes in our sight, choose tight containers, do it right!
Stories
Imagine a treasure chest full of gems (analytes), once left unsealed, they scattered (volatilization) and some stuck to the chest (adsorption). Keep it sealed tight to keep all treasures safe!
Memory Tools
Remember A.R.T. for analyte retention: Adsorption, Reaction, Transport care.
Acronyms
V.A.R. means Volatilization, Adsorption, Reaction to remember loss types.
Flash Cards
Glossary
- Volatilization
The process by which a substance transitions from a liquid or solid phase into a gas phase, often leading to analyte loss during transportation.
- Adsorption
The adhesion of molecules from a liquid or gas to a solid surface, which can lead to decreased concentrations of analytes in samples.
- Quality Assurance (QA)
Planned and systematic activities to ensure that the analysis meets specified requirements for quality.
- Quality Control (QC)
The operational techniques and activities used to fulfill quality requirements.
- Headspace
The unoccupied space above the liquid in a container which can allow for volatilization.
- Matrix Effect
The influence of co-existing substances in a sample that can affect the response of the analyte in analytical methods.
Reference links
Supplementary resources to enhance your learning experience.